High Performance Circuit Breakers & Battery Isolation Switches
High performance circuit breakers are ideally suited to protect against overcurrent and short circuit for use in aircraft and vehicles and other specialised equipment where safety is paramount.
Battery isolation switches are ideally suited for installation in the main battery systems of heavy duty vehicles including tankers, boats, off-road plant and other battery-powered equipment.
High performance circuit breakers feature thermal or thermal-magnetic trip and an extremely high rupture capacity. Battery isolation switches are also based on a thermal-magnetic trip mechanism. The thermal part of the circuit breaker provides delayed protection in the event of overload, the magnetic part disconnects the faulty circuit in the event of overload or short circuit within milliseconds.
Customized High Performance Circuit Breakers such as SG, AP or CBM types are available on request. All products of this group provide genuine physical contact isolation.
410 Circuit Breaker
Various mounting methods, toggle operated
Single (type 410), double (type 520) and three pole (type 530) high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism and toggle actuation (S-type TM CBE to EN 60 934; also to EN 60 947).
Available with a choice of characteristic curves and optional auxiliary contacts.
412 Circuit Breaker
Threadneck mounting, push-pull actuation
Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position.
Threadneck panel mounted and available in tracked vehicle, aircraft and general purpose versions.
413 Circuit Breaker
Threadneck mounting, push-pull actuation
Single pole high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position.
Threadneck panel mounted and available in tracked vehicle, aircraft and general purpose versions.
437 Circuit Breaker
With remote trip coil, toggle operated
Single pole high performance thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and toggle actuation (S-type TM CBE to EN 60934).
Options include auxiliary contacts, a moulded flame retardant enclosure for added environmental protection, and remote operation – disconnection only, or disconnection and re-connection.
446 / 447 / 449 Circuit Breaker
Base mounting, special dual button manual release
Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset snap action mechanism and special dual button manual release which avoids the danger of unintended disconnection (M-type TM CBE to EN 60934).
Compact design available with fast acting, standard and delayed switching characteristics. Options include auxiliary contact and remote electrical disconnection
452 Circuit Breaker
Threadneck mounting. Push-pull actuation
Single pole high performance thermal-magnetic circuit breaker, with tease-free, trip-free, snap action mechanism and push/pull on/off actuation (M-type TM CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position.
482 Circuit Breaker
Threadneck mounting. Push-pull opeation
Single pole compact high performance thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position.
483 Circuit Breaker
Temperature compensated and explosion proof. Aircraft style
Single pole, miniaturised, aircraft style thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position.
Advanced two-chamber design contributes to fail-safe operation. Temperature compensated from -55° to +125 °C, with optional auxiliary contacts.
4120 Circuit Breaker
Temperature compensated and explosion proof. Threadneck mounting.
Single pole, miniaturised thermal circuit breaker with trip-free mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). Threadneck panel mounted, temperature-compensated, with optional auxiliary contacts. Fully approved for commercial aircraft and similar requirements.
4140 Circuit Breaker
Threadneck mounting. SIngle pole. Robust design.
Single pole, thermal circuit breaker with trip-free mechanism, push/pull on/off manual actuation (M-type TO CBE to EN 60934) and temperature compensation. An indicator band on the push button clearly shows the tripped/off position.
The robust design makes type 4140 suitable for extremely harsh conditions.
5140 Circuit Breaker
Threadneck mounting. 3-pole. Robust design.
Three pole, aircraft style thermal circuit breaker with trip-free mechanism and push/pull on/off manual actuation. An indicator band on the push button clearly shows the tripped/off position.
The robust design is well suited to extremely harsh conditions. In the event of an overload in one, two or three phases all three poles will be disconnected.
520 / 530 Circuit Breaker
With toggle actuaction, 2-pole or 3-pole
Single (type 410), double (type 520) and three pole (type 530) high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism and toggle actuation (S-type TM CBE to EN 60 934; also to EN 60 947).
Designed for rail, panel or surface mounting. Available with a choice of characteristic curves and optional auxiliary contacts.
583 Circuit Breaker
Threadneck mounting. Temperature compensated and explosion proof.
Three pole, miniaturised, aircraft style thermal circuit breaker with tease-free, trip-free, snap action mechanism and push/pull on/off manual actuation (M-type TO CBE to EN 60934). An indicator band on the push button clearly shows the tripped/off position.
Advanced two-chamber design minimises contact contamination to provide fail-safe operation. Temperature compensated with optional auxiliary contacts, and fully approved for use on a wide range of aircraft and equipment.
9510 Circuit Breaker
Threadneck mounting. Miniaturised design. For Aircraft simulator
Single pole, miniaturised aircraft simulator switch with extremely fast magnetic trip time. Blade, screw and wire wrap terminals. Aircraft style threadneck and push/pull button with white trip indicator ring.
Current rating marked on the push button according to customer’ s request by adhesive labels or marking inserts.
LET’S GET TOGETHER
We are here to help and answer any question you might have.
Looking for a specific item, need help to design customised system or just want to know more about us – we look forward to hearing from you.